User’s Manual 2008
Power Commander IQ
Network Controlled
SPDU8-1U, SPDU16-2U, SPDU20-0U
Wiremold/Legrand
®
electrical systems conform to and should be properly grounded in compliance with requirements of the current National
Electrical Code or codes administered by local authorities. All electrical products may present a possible shock or fire hazard if improperly
installed or used. Wiremold/Legrand electrical products may bear the mark as UL Listed and/or Classified and should be installed in
conformance with current local and/or the National Electrical Code.
1 007 627 0408
© Copyright 2008 Wiremold / Legrand All Rights Reserved
Vue de la page 0
1 2 3 4 5 6 ... 20 21

Résumé du contenu

Page 1 - User’s Manual 2008

User’s Manual 2008Power Commander IQNetwork ControlledSPDU8-1U, SPDU16-2U, SPDU20-0U Wiremold/Legrand®electrical systems conform to and should be prop

Page 2

73.9 AutoPing and Power Reboot:Each power outlet has optional settings that a NP system usesto ping network equipment. The pinged equipment is attach

Page 3 - TABLE OF CONTENTS

85.1 Starting Configuration Menu:There are four ways to start the Configuration Menu: 1) Local Master Port access method. Run a terminal programfrom

Page 4 - 1 SYSTEM DESCRIPTION

9From Figure 15, System Main Menu (Terminal Screen):Option 1 - Reboot a power outlet: Reboots a power outlet.Rebooting executes if the outlet is unres

Page 5 - 1.3 Front and Back Panel:

105.3 System Access Setup Menu• System(Device) name: Assign a system name, sometimesreferred as site or device name.• Date and Time: Enter calendar d

Page 6 - 3 ACCESS TO THE SYSTEM

115.4 TCP/IP Network Configuration Menu:This is a submenu of System Main Menu.• Obtain IP using DHCP: Enable or disable DHCP. The purpose of using DH

Page 7 - 3.5 Telnet Access:

125.5 More about Emailing Access:5.5.1 Sending Control command to the system:A control command is placed in the email subject field. It hasthe follow

Page 8 - 3.8 SNMP Information:

• Baud Rate: The system supports the following baud rates:2400, 4800, 9600, 19200, 38400, 57600 and 115200. It isstrongly recommended that Master port

Page 9

14• Power Outlet Name: Define a name for the power outlet. • Power Outlet: Set the power outlet to power on or off state. • Power Outlet Timer: Enable

Page 10 - 4 USING CONTROL COMMAND

• Timer Start Time: Specify starting time for the timer. Thestarting time is the actual calendar date and real-time clock.Once a timer reaches this sp

Page 11 - 5 USING CONFIGURATION MENU

165.8 User Account Management Menu:User account management includes reserving or un-reservingeach serial console ports and power outlets to a current

Page 12

Copyright Notice Copyright©2008 by Wiremold/Legrand. The material discussedin this manual is the proprietary property of Wiremold/Legrand.AII retains

Page 13 - 5.3 System Access Setup Menu

Wiremold/Legrand warrants, to the original purchaser or owneronly, that any product manufactured and sold byWiremold/Legrand will be substantially fre

Page 14

RS-232 — DB9 FEMALE RJ45 (8-PIN)RJ45 (8-PIN)RS-232 — DB9 MALE18APPENDIX B SERIAL CONSOLE PORT INTERFACESPIN # NAME LONG NAME DIRECTION DESCRIPT

Page 15

1 SYSTEM DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 16 - 5.7 Power Outlet Setup Menu:

11.1 Products Comparison Chart:1 SYSTEM DESCRIPTIONThe above listed systems provide secure and versatile powerreboot management access for communicat

Page 17

2equipment stops responding the ping request, the equipmentwill be power rebooted.• Scheduling AC outlet power cycling periodically or perweekly plann

Page 18

31. Power Outlet status LEDs: Visual indication of user poweroutlet On/Off status.2. NP system power On/Off status LED: Indication of system power On/

Page 19

43.2 User Privileges and Port Reservations:All user levels, including anonymous (visitor), are able to accessthe system via a serial connection from

Page 20

53.6 Web Access:You need to obtain the system IP address before starting webaccess to the system. Please refer to the Telnet Access sectionfor method

Page 21 - PIN # SIGNAL

6Figure 12 - Implemented MIB Description, List of MIB objectDEFINITION OID RETURNED MESSAGEsystemModel .1.1 System Model number. Read only.systemName